| description: | Products description
A. Summarize
DDS950 Single-phase electronic meter (guide way installation type) uses large-scaled integrate circuit, SMT technics, world-famous branded long-life components and 5+2 digits wide-temperature LCD. It can measure the 50Hz~60Hz three-phase AC active consumption accurately. It meets all the technical requirements of the standard GB/T17215-2002 (idt IEC61036 international standard) and some other relative national standard. Good reliability, wide load, low consumption, highly accuracy without calibration for long time, anti-tampering and good anti-disturbance performance.
B. Main function and characteristic
1. Can measure the positive and reverse active consumption and accumulate the reverse consumption to positive consumption.
2. Uses passive photo-electric insulation technique to output passive electronic impulse and LED to show power consumption.
3. Good reliability, wide load, low consumption, high accuracy without calibration for long time, anti-tampering and good anti-disturbance performance.
4 .LCD shows information directly.
5. Rail type installation and conveniently for setting.
C. Technical date
|
Class |
1 or 2 |
|
Voltage circuit consumption |
≤1W & 6VA |
|
Reference voltage |
110V, 120V, 220V, 230V, 240V |
|
Basic current (rated max, current) |
2.5(10)A, 5(20)A, 5(30)A, 10(40)A, 10(60)A, 15(60)A |
|
Limited working temperature |
-25℃~+55℃ |
|
Relative humidity |
≤85% |
|
Standard |
The standard of GB/T 17215-2002《Class 1 and Class 2 static AC active meter》idt IEC61036 |
|
Other technical parameter |
Impulse width 80ms±20ms | |